Eurobatt AGM Battery

Technical Specification

Model   No Rated Voltage(V) Capacity (Ah) Dimension Weight Terminal Type
Length Width Height Total   Height kg pound
mm inch mm inch mm inch mm inch
12V Front Access AGM Battery for   Telecommunications/IT Applications
NPF55-12 12 55 277 10.91 106 4.17 222 8.74 222 8.74 16.5 36.3 T2-M6
NPF80-12 12 80 562 22.13 114 4.49 188 7.40 188 7.40 25.0 55.0 T3-M6
NPF100-12 12 100 507 19.96 110 4.33 228 8.98 228 8.98 29.5 64.9 T4-M8
NPF110-12 12 110 394 15.51 110 4.33 286 11.26 286 11.26 30.5 67.1 T4-M8
NPF125-12 12 125 551 21.69 110 4.33 240 9.45 240 9.45 37.8 83.2 T4-M8
NPF150-12 12 150 551 21.69 110 4.33 288 11.34 288 11.34 45.0 99.0 T4-M8
NPF155-12 12 155 560 22.05 125 4.92 280 11.02 280 11.02 45.2 99.4 T4-M8
NPF160-12 12 160 551 21.69 110 4.33 288 11.34 288 11.34 45.6 100.3 T4-M8
NPF175-12 12 175 546 21.50 125 4.92 321 12.64 321 12.64 53.7 118.1 T5-M8
NPF180-12 12 180 560 22.05 125 4.92 316 12.44 316 12.44 54.0 118.8 T5-M8
NPF180-12B 12 180 560 22.05 125 4.92 316 12.44 316 12.44 55.5 122.1 T5-M8
NPF190-12 12 190 560 22.05 125 4.92 316 12.44 316 12.44 55.8 122.8 T5-M8
NPF190-12B 12 190 560 22.05 125 4.92 316 12.44 316 12.44 58.0 127.6 T5-M8
NPF200-12 12 200 560 22.05 125 4.92 316 12.44 316 12.44 57.0 125.4 T5-M8
NPF200-12B 12 200 560 22.05 125 4.92 316 12.44 316 12.44 59.0 129.8 T5-M8


Main Features

• 12 years design life at floating condition

• Wide operating temperature range from -15°C to 55°C

• Advanced paste formula with increased recharge efficiency

• Front access terminal with standard width for 19” and 23” ETSI racks

• 30% decreased float current lead to excellent high temperature resistance

• Thick flat plate with high Tin low Calcium alloy

• Low self-discharge rate

• Excellent deep discharge recovery capability

-Low self-discharge rate

-Excellent deep discharge recovery capability

Applications

• 19" and 23" standard power cabinet                                                                 

• communication system, microwave station, mobile base station, data center,    

   radio / broadcasting station                                                                      

• Power system of special network or local area network                                                      

• Emergency lighting and signal system                                                                

• UPS, Standby power, etc  

Terminal Chart

Documents

1.DCG series-Deep Cycle Gel Battery Brochure
2.

I Want To Purchase